Warning: include(/home/quintpub/public_html/journals/prd/includes/code.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 2

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prd/includes/code.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 2
Prospective 1-Year Study of Immediately Loaded Implants: 8-Patient Case Series Report
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 39 , Issue 4
July/August 2019

Pages 469–477


Prospective 1-Year Study of Immediately Loaded Implants: 8-Patient Case Series Report

Marc L. Nevins, DMD, MMSc/Marcelo Camelo, DDS/Anthony Prudenti, DDS, MS/Soo-Woo Kim, DMD, DMSc, MS/Raquel Borges Camelo Surette, DDS, MS/Julie Mitchell, DDS, MS


PMID: 30990478
DOI: 10.11607/prd.4316

The goal of this case series report is to demonstrate the predictability of providing immediate restorations with an implant specifically designed to achieve high primary stability, and to report on 12-month survival outcomes. Twenty-nine implants were placed in eight patients with various tooth-replacement needs, from single teeth to partially edentulous spans to fully edentulous mandibles. A new tapered-implant system (The Marc Nevins, Little Implant) was utilized that incorporates a self-tapping thread design with a thread pitch and thread lead to improve primary stability at insertion. All implants were placed with a minimum insertion torque of 45 Ncm. Four immediate implants and two early placements at extraction sites were included in the cohort. Twenty-seven implants were clinically successful at 1 year. Two implants in a healed ridge were found to have failed at 6 weeks postoperative in one patient wearing an ill-fitting removable partial denture. The radiographic crestal marginal bone levels were recorded in millimeters from the top of the implant platform to the first bone-to-implant contact. The mean crestal marginal bone level change was –0.57 ± 0.82 mm. This case series report demonstrates the ability of an implant designed for high primary stability to achieve successful integration in the presence of an immediate restoration for various clinical presentations, including single-tooth, multi-unit, and edentulous cases.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

PRD Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help